innovaphone IP6013

Delivery Contents

  • End device IP6013
  • Accompanying document with QR code

Technical Data

Power supply PoE+ according to IEEE 802.3at, class 4
Operation temperature: 0 °C to +45 °C
Storage temperature: -10 °C to +70 °C
Humidity: 10% to 90% (non-condensing)

Intended Use

This device is suitable for connection

  • to Deutsche Telekom AG’s ISDN network or other technically comparable networks according to the harmonized European standard CTR 4
  • to the innovaphone PBX or SIP server or technically comparable systems according to the international H.323 or SIP standards

The existing interfaces may only be used for appropriate purposes as follows:

Symbol Use
PRI 1…PRI 4 RJ45 (modular jack 8P8C) connector for ISDN primary multiplex interface
ETH0, ETH1 RJ45 (modular jack 8P8C) connector for Ethernet (LAN)

Pinout for PRI Interfaces

PIN Pinout
PIN 1 Receive +
PIN 2 Receive -
PIN 3 TX +
PIN 4 TX -

Warranty

Contact the specialist dealer in case of warranty. Improper use voids warranty.

Serial Number

The serial number and the hardware version for this device can be found underneath the device.

Declaration of Conformity

The company innovaphone AG, Umberto-Nobile-Straße 15, 71063 Sindelfingen, Germany, declares its sole responsibility that the products below comply with the basic requirements and other relevant provisions of the EMC directive 2014/30/EU and the RoHS directive 2011/65/EG when used properly. The following standards have been applied:

Product:

  • VoIP gateway innovaphone IP6013 (Art. Nr. 01-06013-001)

Directives and Standards Applied:

  • EN 55032:2015
  • EN 61000-4-2:2009
  • EN 61000-4-3:2006 + A1:2008 + A2:2010
  • EN 61000-4-4:2012
  • EN 61000-4-5:2014
  • EN 61000-4-6:2014
 

FCC Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
 

 

Sindelfingen - January 19, 2021
Carsten Bode - Head of Development

Carsten Bode
back

This website uses cookies to provide you with an optimal website experience. This includes cookies that are necessary for the operation of the website, as well as cookies that are only used for anonymous statistical purposes or for convenience settings to display special content. You can decide for yourself which settings you would like to allow. Please note that not all functionalities of the website might be available, depending on your settings. If you accept all cookies, you will have full access to all the services of our website. For further information, please read our privacy policy.

   